BLJBB - INNOVA NITRATE B REAGENT

Product Identification

Product ID:INNOVA NITRATE B REAGENT
MSDS Date:01/01/1988
FSC:6550
NIIN:00N020754
MSDS Number: BLJBB

Responsible Party
INNOVATIVE DIAGNOSTIC SYSTEMS INC
3404 OAKCLIFF ROAD C-1
ATLANTA, GA 30340
US

Emergency Phone: 404-457-2691

Info Phone: 404-457-2691

Cage: 67290

Contractor
INNOVATIVE DIAGNOSTIC SYSTEMS, INC
ATLANTA, GA 30340 US

Telephone: 404-457-2691

Cage: 67290

Ingredients

ACETIC ACID (SARA III)

CAS: 64-19-7

RTECS: AF1225000

Fraction By Weight: 28.4%

OSHA PEL 10 PPM

ACGIH TLV: 10 PPM/15 STEL; 9192

EPA Report Quantity: 5000 LBS

DOT Report Quantity: 5000 LBS


1-NAPHTHYLAMINE, N,N-DIMETHYL-;

CAS: 85-56-6

RTECS: QM2825000

Fraction By Weight: 0.6%


THE HAZARDS OF THIS MIXTURE HAVE NOT BEEN INVESTIGATED.

RTECS: 9999999ZZ

Hazards

LD50 LC50 Mixture:SEE INGREDIENT 1
Routes of Entry: Inhalation:YES Skin:NO Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACETIC ACID:AN EYE, MUCOUS MEMBRANE &
SKIN IRRITANT. SKIN SENSITIZER.
N,N-DIMETHYL-1-NAPHTHYLAMINE:POSSIBLE CARCINOGEN. AN EYE, SKIN &
MUCOUS MEMBRANE IRRITANT.
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:NONE SPECIFIED BY MANUFACTURER.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:SKIN:IMMEDIATELY FLUSH AREA W/COPIOUS AMOUNTS OF WATER & WASH
W/SOAP. EYE:FLUSH W/COPIOUS AMOUNTS OF WATER FOR AT LEAST 15 MINS.
ASSURE ADEQUATE FLUSHING BY SEPARATING EYELIDS W/FINGERS. SEEK MD.
INGE ST:IF VICTIM IS CONSCIOUS, GIVE SODIUM BICARBONATE & INDUCE
VOMITING. SEEK MD. INHAL:REMOVE TO FRESH AIR. SUPPORT BREATHING
(GIVE O2/ ARTIFICIAL RESPIRATION) .

Fire Fighting

Extinguishing Media:WATER SPRAY, CARBON DIOXIDE, DRY CHEMICAL POWDER OR
FOAM.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA & FULL
PROTECTIVE EQUIPMENT . AVOID BREATHING VAPORS. AVOID SKIN, EYE AND
CLOTHING CONTACT.
Unusual Fire/Explosion Hazard:NONE SPECIFIED BY MANUFACTURER.

Accidental Release

Spill Release Procedures:WEAR RUBBER GLOVES & WASH SPILL STIE WITH
WATER.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:FOR IN VITRO DIAGNOSTIC USE. DO NOT
REMOVE MATERIAL FROM ORIGINAL PACKAGE.
Other Precautions:NONE SPECIFIED BY MANUFACTURER.

Exposure Controls

Respiratory Protection:WEAR NIOSH/MSHA APPROVED RESPIRATOR FOR EXPOSURE
OF CONCERN .
Ventilation:NONE SPECIFIED BY MANUFACTURER.
Protective Gloves:IMPERVIOUS GLOVES (FP N).
Eye Protection:CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:NONE SPECIFIED BY MANUFACTURER.
Work Hygienic Practices:AVOID CONTACT W/SKIN, EYES OR CLOTHING.
Supplemental Safety and Health
NONE SPECIFIED BY MANUFACTURER.

Chemical Properties

HCC:C2
Appearance and Odor:CLEAR TO PALE YELLOW FREE FLOWING LIQUID.

Stability

NONE SPECIFIED BY MANUFACTURER.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:NONE SPECIFIED BY MANUFACTURER.

Disposal

Waste Disposal Methods:DISPOSAL MUST BE IN ACCORDANCE W/FEDERAL, STATE
& LOCAL REGULATIONS .

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.